Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Micheau, C.; Ueda, Yuki; Motokawa, Ryuhei; Akutsu, Kazuhiro*; Yamada, Norifumi*; Yamada, Masako*; Moussaoui, S. A.*; Makombe, E.*; Meyer, D.*; Berthon, L.*; et al.
Journal of Molecular Liquids, 401, p.124372_1 - 124372_12, 2024/05
Supramolecular organization of extractant molecules impacts metal ions separation behavior. Probing bulk and interfacial structures of the relevant systems is expected to provide key insights into the metal ion selectivity and kinetic aspects. The supramolecular features of two solvent extraction systems based on malonamide extractants THMA in toluene and DBMA in n-heptane were studied using small-angle X-ray scattering for the organic bulk phases, as well as interfacial tension and neutron reflectivity measurements for the interfaces. In the bulk solution, THMA forms dimeric/trimeric associates but no aggregates in toluene, while DBMA forms large aggregates in n-heptane. On the other hand, THMA accumulates in a diffuse layer at the interface at high THMA concentration, whereas DBMA forms a compact but thinner layer. After Pd(II) extraction, the thickness of interfacial layers decreases in the case of THMA, and totally vanishes in the case of DBMA. Based on these new structural information, two mechanisms are proposed for Pd(II) and Nd(III) extraction with malonamides. In toluene, THMA associates slightly accumulate in the vicinity of the interface, then coordinate Pd(II) and diffuse into the organic bulk phase. In n-heptane, DBMA aggregates adsorb at the interface then pick up Nd(III) cations in their polar cores and finally diffuse into the bulk.
Shamoto, Shinichi; Akatsu, Mitsuhiro*; Chang, L.-J.*; Nemoto, Yuichi*; Ieda, Junichi
Applied Physics Letters, 124(11), p.112402_1 - 112402_5, 2024/03
The magnon excitation by ultrasound injection in YFeO is studied by inelastic neutron scattering. Both longitudinal and transverse ultrasound injections enhanced the inelastic neutron scattering intensity.
Yamauchi, Hiroki; Sari, D. P.*; Yasui, Yukio*; Sakakura, Terutoshi*; Kimura, Hiroyuki*; Nakao, Akiko*; Ohara, Takashi; Honda, Takashi*; Kodama, Katsuaki; Igawa, Naoki; et al.
Physical Review Research (Internet), 6(1), p.013144_1 - 013144_9, 2024/02
Okita, Shoichiro; Goto, Minoru
Proceedings of 12th International Conference on Nuclear Criticality Safety (ICNC2023) (Internet), 10 Pages, 2023/10
Kawamura, Seiko
Neutron News, 34(2), p.2 - 3, 2023/04
Iwase, Hiroki*; Akamatsu, Masaaki*; Inamura, Yasuhiro; Sakaguchi, Yoshifumi*; Morikawa, Toshiaki*; Kasai, Satoshi*; Ouchi, Keiichi*; Kobayashi, Kazuki*; Sakai, Hideki*
Journal of Applied Crystallography, 56(1), p.110 - 115, 2023/02
Times Cited Count:2 Percentile:85.44(Chemistry, Multidisciplinary)With the increasing importance of light-responsive materials, it is vital to analyze the relationship between function and structural changes induced by light irradiation. Small-angle scattering (SAS) is effective for such structural analysis. However, quantitatively capturing local molecular structure formation and molecular reactions at a scale of less than 1 nm via SAS is difficult. In this study, to analyze the structure of non-equilibrium phenomena in light-responsive materials, a new sample environment has been developed for a time-of-flight small- and wide-angle neutron scattering instrument (TAIKAN), comprising a UV-Vis irradiation system, UV-Vis absorption measurement equipment and photodetector. Simultaneous measurement of small-angle neutron scattering and UV-Vis absorption was achieved. This system was used to demonstrate the in situ observation of UV-Vis irradiation-induced structural change of micelles formed by a light-responsive surfactant sample in an aqueous solution.
Wu, P.*; Murai, Naoki; Li, T.*; Kajimoto, Ryoichi; Nakamura, Mitsutaka; Kofu, Maiko; Nakajima, Kenji; Xia, K.*; Peng, K.*; Zhang, Y.*; et al.
New Journal of Physics (Internet), 25(1), p.013032_1 - 013032_11, 2023/01
Times Cited Count:0 Percentile:0(Physics, Multidisciplinary)Kim, G.*; Im, S.*; Jee, H.*; Suh, H.*; Cho, S.*; Kanematsu, Manabu*; Morooka, Satoshi; Koyama, Taku*; Nishio, Yuhei*; Machida, Akihiko*; et al.
Cement and Concrete Research, 159, p.106869_1 - 106869_17, 2022/09
Times Cited Count:16 Percentile:87.96(Construction & Building Technology)Wang, Q.*; Hu, Q.*; Zhao, C.*; Yang, X.*; Zhang, T.*; Ilavsky, J.*; Kuzmenko, I.*; Ma, B.*; Tachi, Yukio
International Journal of Coal Geology, 261, p.104093_1 - 104093_15, 2022/09
Times Cited Count:5 Percentile:69.58(Energy & Fuels)Omasa, Yoshinori*; Takagi, Shigeyuki*; Toshima, Kento*; Yokoyama, Kaito*; Endo, Wataru*; Orimo, Shinichi*; Saito, Hiroyuki*; Yamada, Takeshi*; Kawakita, Yukinobu; Ikeda, Kazutaka*; et al.
Physical Review Research (Internet), 4(3), p.033215_1 - 033215_9, 2022/09
Tripathi, R.*; Adroja, D. T.*; Ritter, C.*; Sharma, S.*; Yang, C.*; Hillier, A. D.*; Koza, M. M.*; Demmel, F.*; Sundaresan, A.*; Langridge, S.*; et al.
Physical Review B, 106(6), p.064436_1 - 064436_17, 2022/08
Times Cited Count:2 Percentile:34.67(Materials Science, Multidisciplinary)Hori, Satoshi*; Kanno, Ryoji*; Kwon, O.*; Kato, Yuki*; Yamada, Takeshi*; Matsuura, Masato*; Yonemura, Masao*; Kamiyama, Takashi*; Shibata, Kaoru; Kawakita, Yukinobu
Journal of Physical Chemistry C, 126(22), p.9518 - 9527, 2022/06
Times Cited Count:3 Percentile:41.53(Chemistry, Physical)Arai, Yosuke*; Kuroda, Kenta*; Nomoto, Takuya*; Tin, Z. H.*; Sakuragi, Shunsuke*; Bareille, C.*; Akebi, Shuntaro*; Kurokawa, Kifu*; Kinoshita, Yuto*; Zhang, W.-L.*; et al.
Nature Materials, 21(4), p.410 - 415, 2022/04
Times Cited Count:7 Percentile:77.62(Chemistry, Physical)Tominaga, Masahide*; Nagayasu, Yukari*; Sasaki, Motoharu*; Furuta, Takuya; Hayashi, Hiroaki*; Oita, Masataka*; Nishiyama, Yuichi*; Haga, Akihiro*
Radiological Physics and Technology, 14(4), p.381 - 389, 2021/12
Due to recent advance of diagnostic radiology, the increase of diagnostic radiation exposure to patient becomes problem. Diagnostic Reference Levels has been released to optimized the radiation exposure to patients in Japan recently. The evaluation of entrance surface dose (ESD) is recommended to assess the dose level for general X-ray examination. The ESD can be easily evaluated by multiplying the backscatter factor of the patient body on the free-in-air air kerma. The air kerma free-in-air value used to estimate ESD may contain X-rays scattered from obstacles located at the time of measurement, which may induce non-minor error in assessments. We therefore studied the influence of scattered X-rays on air kerma measurement under various environments (distances, field sizes, and materials). It was found that the dependence on the X-ray energy and field size was different for different materials. The X-ray contamination can be ignored for all the materials when the distance to the scatterer exceeds 35 cm.
Hashimoto, Shunsuke*; Nakajima, Kenji; Kikuchi, Tatsuya*; Kamazawa, Kazuya*; Shibata, Kaoru; Yamada, Takeshi*
Journal of Molecular Liquids, 342, p.117580_1 - 117580_8, 2021/11
Times Cited Count:3 Percentile:27(Chemistry, Physical)Quasi-elastic neutron scattering (QENS) and pulsed-field-gradient nuclear magnetic resonance (PFGNMR) analyses of a nanofluid composed of silicon dioxide (SiO) nanoparticles and a base fluid of ethylene glycol aqueous solution were performed. The aim was to elucidate the mechanism increase in the thermal conductivity of the nanofluid above its theoretical value. The obtained experimental results indicate that SiO particles may decrease the self-diffusion coefficient of the liquid molecules in the ethylene glycol aqueous solution because of their highly restricted motion around these nanoparticles. At a constant temperature, the thermal conductivity increases as the self-diffusion coefficient of the liquid molecules decreases in the SiO nanofluids.
Matsuura, Masato*; Yamada, Takeshi*; Tominaga, Taiki*; Kobayashi, Makoto*; Nakagawa, Hiroshi; Kawakita, Yukinobu
JPS Conference Proceedings (Internet), 33, p.011068_1 - 011068_6, 2021/03
The position dependence of the scattered intensity in the time-of-flight backscattering spectrometer DNA was investigated. A periodic structure for both vertical (pixel) and horizontal (PSD) directions was observed. The solar slit and over-bending of an analyzer crystal is discussed as a possible origin of the modulation in the intensity. We have developed software program for the systematic correction of the position-dependent intensity and offset energy for the elastic peak. This corrects the deviation from the true scattering intensity and improve the quality of the data, which includes the energy resolution.
Tominaga, Taiki*; Kobayashi, Makoto*; Yamada, Takeshi*; Matsuura, Masato*; Kawakita, Yukinobu; Kasai, Satoshi*
JPS Conference Proceedings (Internet), 33, p.011095_1 - 011095_5, 2021/03
A vertical movement type of sample changer for the neutron spectrometer BL02, J-PARC MLF was developed for our top-loading type cryostat. The sample changer, termed as "PEACE", can control reproducibility of the irradiated position using guides made of polyether ether ketone. The variation between the background scattering profiles of three sample positions was found to be less than plus minus 1.6%. This result is reasonable, considering the deviation of sample position of less than plus minus 0.3 mm from the vertical axis.
Tominaga, Taiki*; Kawakita, Yukinobu; Nakagawa, Hiroshi; Yamada, Takeshi*; Shibata, Kaoru
JPS Conference Proceedings (Internet), 33, p.011086_1 - 011086_5, 2021/03
We developed a quartz double cylindrical sample cell optimized for a backscattering neutron spectrometer, especially for BL02 (DNA), MLF in J-PARC. A quartz glass tube, with one end closed, is shaved to obtain a wall thickness of 0.55 mm. The inner tube is properly centered using a protrusion into the outer tube such that the interstice between the outer and inner tubes keeps constant. This quartz cell can be used for samples that should not be in contact with the aluminum surface. We verified cell's background effect between the quartz cell and Al cell by QENS measurements using DO buffer. The elastic intensity profiles of the buffer in a low Q region were identical between both quartz cell and Al cell (A1070). In a high Q region, however, the profiles were different caused by the first sharp diffraction peak of quartz glass. For this region the data should be analyzed by consideration of absorption correction and diffraction in individual thickness of quartz cell.
Zhai, Y.*; Luo, P.*; Nagao, Michihiro*; Nakajima, Kenji; Kikuchi, Tatsuya*; Kawakita, Yukinobu; Kienzle, P. A.*; Z, Y.*; Faraone, A.*
Physical Chemistry Chemical Physics, 23(12), p.7220 - 7232, 2021/03
Times Cited Count:3 Percentile:27(Chemistry, Physical)Terranova, N.*; Aberle, O.*; Alcayne, V.*; Kimura, Atsushi; 125 of others*
EPJ Web of Conferences, 239, p.01024_1 - 01024_5, 2020/09
Times Cited Count:4 Percentile:95.3(Nuclear Science & Technology)